GENERATOR (4 STROKE)
SAFETY AND OPERATING INSTRUCTIONS
For your own safety and for the safety of oth-
ers, please read these instructions carefully
before using this appliance. It will help you
understand your product more easily and avoid un-
necessary risks. Keep this instruction manual in a
safe place for future use.
1. MACHINE DATA
INTRODUCTION
The generator is designated to generate electricity with
help of a 4 stroke fuel engine. Now you can use your
electric tools in the fi eld in spite of the lack of the elec-
tricity grid.

TECHNICAL SPECIFICATION

Rated voltage
Rated frequency
Rated output
Tool class
Weight
Type Engine
Cylinder arrangement
Displacement
Max. output
Operation hours
Fuel
Fuel tank capacity
Engine oil capacity
6
AC 230 V; DC 12 V
50 Hz
2,0 kVA
1
44 kg
Air cooled
4-stroke petrol
Inclined, 1 cylinder
163 cm
3
2,5 kVA
8.2
Unleaded petrol
15 L
0,6 L
1
FEATURES
1. Fuel cap
2. Fuel level gauge
3. Oil warning light
4. Engine switch
5. Pilot light
6. AC switch
7. Oil drain plug
8. Fuel tank
9. Ground terminal
10. Exhaust screen
11. AC sockets
12. Oil fi ller cap
13. Exhaust
14. Spark plug
15. Choke lever
16. Recoil starter
17. Fuel tap
18. Air fi lter cover
19. Voltmeter
20. DC socket
21. Fuse
2. SAFETY INSTRUCTIONS
Explanation of symbols
In this manual and/or on the machine the following
symbols are used:
In accordance with essential applicable safety
standards of European directives
Risk of damaging material and/or physical in-
juries
Risk of an electric shock
Read instruction manual
Keep bystanders away
Do not expose to rain
Outdoor noise
Risk of high temperature Caution: the com-
pressor contains some parts which might reach
high temperatures
SAFETY INSTRUCTIONS
Persons
• Never allow children or people unfamiliar with these
instructions to use the appliance. Local regulations
may restrict the age of the operator.
• Always operate outdoors with good ventilation. Ex-
haust gas contains poisonous carbon monoxide.