refrigerator. (Fig. 5) The defrost water will evaporate
automatically into the circulating air and the vessel will
not need emptying.
To switch off the unit, disconnect the refrigerator from
the electricity supply and leave the cabinet door open.
After defrosting the cabinet interior should be wiped
out with a clean, damp cloth.

7.1. Automatic defrost function

The first defrosting phase commences 39 hours after
the start and lasts for two hours.
After this, the device operates for 22 hours at a time,
followed by a defrosting period of 2 hours.

7.2. Interior light

Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door is
opened.
Two sensors (B) control whether the door is open or
not and the LEDs and the door control as well will
work accordingly.

8. Reversing the door hang

The direction the door opens can be transferred from
one side to the other by carrying out the following
steps:
disconnect the mains
lay the refrigerator down carefully on its back
remove the lower hinge
remove the two upper left-hand screws and detach
the covering plate

10. Customer service

Before you call a service engineer, carry out the
following simple tests:
Problem
The appliance does not cool sufficiently
The appliance does not cool at all.
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serial-number are
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
8
(fig. 6.)
(Fig. 7, 8.)
and detach the door
by pulling it forward
Too much food to be cooled was put in.
Door is not shut properly.
Internal air circulation is restricted.
CUC system stopped the operation.
Plug is not connected to the mains socket properly
There is no voltage in the mains socket.
detach the upper hinge and mount it on the
opposite side
remove the hinge bolt and screw it in from below
insert the covering plate in the upper right-hand
corner by pushing it in and secure it with the two
screws
position the door on the upper hinge bolt and
mount the lower hinge
ensure the door can move freely and the seal is
correctly positioned.
Remove the hinge plate
opposite side
9. Replacing the decorative
door panel
(only free-standing model)
Removing and mounting of the door is similar to
that of described in the previous, 8 chapter. (Only
the foot on the hinge-side has to be removed!)
Remove screws (4) and pull off the frame edge (5).
Slide the decorative panel (6) out of the door frame
and insert the new panel (7), so that the upper edge
of the panel runs exactly parallel to the upper edge of
the frame. A new panel can be inserted more easily
into the upper edge of the frame when the two
corners are cut off by approx. 5 x 5 mm (8). Put the
frame edge (5) back in place and secure with screws.
Place the door on the lower hinge (9), slot the
upper hinge into the opening, press together with
the door against the housing and secure with the
two screws (11).
Possible cause
and mount it on the
(Fig. 9-11.)
Solution
Put in less food to be be cooled.
Check if the door is shut.
Provide inside cool air circulation.
See operating instruction 5.3.
Check if the connection is proper.
Check if there is voltage.