  • DEUTSCH, seite 8
GB
8. Defrosting, cleaning and
maintenance
Frost will gradually form on the cooling plate and it
must not be allowed to become too thick since it
restricts the cooling.
This miniBar is fitted with a fully automatic electronic
temperature regulator.
The frost will melt and the defrost water will run
through the drain tube from the drip channel into an
evaporating vessel located at the bottom rear of the
refrigerator. (Fig. 5) The defrost water will evaporate
automatically into the circulating air and the vessel will
not need emptying.
To switch off the unit, disconnect the refrigerator from
the electricity supply and leave the cabinet door open.
After defrosting the cabinet interior should be wiped
out with a clean, damp cloth.

8.1. Automatic defrost function

The first defrosting phase commences 39 hours after
the start and lasts for two hours.
After this, the device operates for 22 hours at a time,
followed by a defrosting period of 2 hours.

8.2. Interior light

Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door is
opened.

9. Customer service

Before you call a service engineer, carry out the
following simple tests:
Problem
The
appliance
does
sufficiently
The appliance does not cool at all.
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serial-number are
6
Figure 3.
(fig. 4.)
not
cool
Too much food to be cooled was put in.
Door is not shut properly.
Internal air circulation is restricted.
CUC system stopped the operation.
Plug is not connected to the mains socket
properly
There is no voltage in the mains socket.
Two sensors (B) control whether the door is open
or not and the LEDs and the door control as well
will work accordingly.
B
8.3. Automatic Door Control LED
(ADC) optional
The LED (Fig. 5.A) indicated whether the miniBar
door has been opened. If so then:
1. Open the miniBar, check the content in the
compartement and if necessary, replenish.
2. Reset the door control signal by helding the
Remote control against the door opening sensor
(Fig. 4. B) and push the button .
3. Close the miniBar.
Possible cause
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your
nearest Service Centre-see local telephone
directory.
A
Figure 4.
Figure 5.
Solution
Put in less food to be be cooled.
Check if the door is shut.
Provide inside cool air circulation.
See operating instruction 5.3.
Check if the connection is
proper.
Check if there is voltage.