10. MAINTENANCE

This Whale® Shower Sump System is designed only to require minimal maintenance.
WARNING - Before servicing, disconnect power and drain system.
Optimal performance
Regularly remove motor housing and inspect and clean filter to be sure that it is not being blocked by debris.
Annual Checks
Whale advise that the boat's plumbing system should be checked at least annually for leaks and obstructions.
Also a pump electrics test is advisable. If you are not familiar with applicable electrical standards. Ensure that
the electric test is completed by a qualified electrician/ technician.
11. WINTERIZING
NOTE - Fully drain system for winterizing.
Whale do not guarantee warranty if the system is not fully drained for winterizing.

12. TROUBLESHOOTING

PROBLEM
Pump runs but does
not pump water / pump
pulses
Pump does not run
Pump continuously
runs
Motor speed variation
when running dry

13. PATENTS AND TRADEMARKS

Whale®, is a registered trademark of Munster Simms Engineering Limited, Bangor Northern Ireland trading as Whale®.
14. DECLARATION OF CONFORMITY, STANDARDS, APPROVALS
This product complies with all relevant European directives and standards. Please contact Whale® if further details are
required.
Manufacturer's Declaration
We hereby declare, under our sole responsibility, that the enclosed equipment complies with the provisions of the
following EC Directives.
Electromagnetic Compatibility Directive 2004/108/EC on the approximation of the laws of the Member States relating to
electromagnetic compatibility.
CE mark affixed: 31st May 2012
Basis on which conformity is declared
The above equipment complies with the protection requirements of the EMC Directive.
Fuse
On - Manual Override
Brown wires with
yellow crimp
Black Wire
POSSIBLE CAUSES
Hose may have
blockage or airlock
Remove pump housing from base. Remove debris from chamber and
Impeller may be
impeller. Ensure that the impeller is firmly attached to shaft and is not
restricted
Blown fuse
Dirt on sensor
Figure 3 - Typical Wiring
Battery
POTENTIAL SOLUTION
Clear the hose of any blockages and ensure that outlet hose runs
upward to the thru-hull connector, with no dips
Ensure electrical connections and fuse are waterproof and have not
Wipe sensor clean
Normal operation
4
cracked or broken
loosened