4. Installation
Hydroboil 15, 25
N PE L1
EN
Heating
indicator
2
2
Hydroboil 40
L1 L2 L3 L4
A1
Relais
A2
T1 T2 T3 T4
Thermostat
L2
L1
PE
N

Electrical connection

Only by a specialist!
Terminal
Please observe:
• VDE 0100
• The installation must comply with current IEC and national local regulations or any
particular regulations, specified by the local electricity supply company
• The rating plate and technical specifications
Thermostat
• The appliance must be earthed!
• All electric cables must be in perfect condition
Surface mounted electrical connection
1. Disconnect the junction box / socket from the power supply.
1
Safety swich
2. If no power cord has yet been installed, use the strain relief bush (cable gland) to
1
lead a cable with a cross­section adapted to the rated current of the Hydroboil into
the appliance and connect it to the connection terminal according to the wiring
diagram.
Note: The power cord of the Hydroboil 40 must be dimensioned to a rated current
of 25 A.
3. Tighten the strain relief bush to secure the power cord.
4. Connect the other end of the power cord to the power supply:
a. When connecting with a plug, plug the earthing contact plug into a
Heating
element 1
Heating
element 2
b. In the case of a permanent connection, connect the power cord to a
Do not turn on the power supply yet!
2
1
2
Safety
switch
Flush mounted electrical connection
1
2
1. Disconnect the power supply line from the power supply.
2. Use the strain relief bush (cable gland) to lead a cable into the appliance and
connect it to the connection terminal according to the wiring diagram.
Heating
indicator
Note: The power cord of the Hydroboil 40 must be dimensioned to a rated current
of 25 A.
3. Tighten the strain relief bush to secure the power cord.
Do not turn on the power supply yet!
correspondingly fused socket (HB15, HB25 only).
Make sure that the socket is grounded.
correspondingly fused junction box. The earth conductor must be used.