ENGLISH
23
23
FILT
1
2
3
esc
/ °C
By-Pass
The operating speed is preset during appliance
configuration, and can be selected by pressing the UP
button briefly (1=min. speed, 2=med. speed, 3=max.
speed).
Set required room temperature (fig.24).
Before proceeding with the steps indicated below, press
the ESC button to exit and return to the initial menu.
24
24
FILT
1
2
3
esc
/ °C
By-Pass
The preferred room temperature can be selected as
follows:
- press and hold the SET button
- press the SET button briefly (the current value flashes)
- select the required value using the UP and DOWN
buttons
- press the SET button briefly to retain the setting
- press the ESC button briefly to exit.
Activate "bypass" function (fig.25)
25
25
FILT
1
2
3
esc
/ °C
By-Pass
The purpose of the bypass function is to ventilate the
22
P1
P2
HA
4
5
6
7
set
Prg
P1
P2
HA
4
5
6
7
set
Prg
HA
P1
P2
4
5
6
7
set
Prg
apartment without heat transfer. With the bypass valve
open, air can be introduced directly from outside,
without passing through the heat exchanger. The flow of
air vented from inside continues to pass through the
heat exchanger.
Before proceeding with the steps indicated below, press
the ESC button to exit and return to the initial menu.
The "bypass" function can be forced by pressing and
holding the ESC button. The corresponding "money
box" icon will light up.
Activate time/outdoor temperature display (fig.26)
Before proceeding with the steps indicated below, press
the ESC button to exit and return to the initial menu.
26
26
FILT
1
2
3
esc
/ °C
By-Pass
The current values of the "time" and "outdoor
temperature" parameters can be viewed in alternation
by pressing the ESC button briefly.
User menu
Before proceeding with the steps indicated below, press
ESC to exit and return to the opening screen.
27
27
FILT
1
2
3
esc
/ °C
By-Pass
As a rule, the parameters relative to the various options
are selected by pressing SET (this causes the current
value to blink), then scrolling through the available
values with the UP and DOWN buttons, and pressing
SET again to confirm the new value. The UP and DOWN
buttons are also used to scroll through the different
options or parameters. The main user menu can be
viewed by pressing and holding ESC and SET at one
and the same time. The options of the menu are:
- PROF: settings for operation with time profiles:
P1, used to program one period of operation per day,
with a start time, an end time and a fan speed;
P1
P2
HA
4
5
6
7
set
Prg
P1
P2
HA
4
5
6
7
set
Prg