Valve system

1. Check the valve system for visible damage, such as deformations, offset, sealing rings, etc.
2. For the screws, ensure a tightening torque of 0.9 Nm ±0.1 Nm.
Fig. 4:
Tightening torque
3. Note the operating mode set on the pilot air cover on the right end plate.
If the pilot air is internal, continue with section 5 Test preparation (from page 29).
Fig. 5:
Pilot selection
4.4

External pilot

If the pilot is external, an additional connection to connection X12/X14 is required on the left end
plate. For the function test, only one connection (X12 or X14) has to be supplied with compressed air.
O
Make sure the operating mode is set correctly on the pilot air cover.
1
Fig. 6:
Pilot air supply X12/X14
1
Fig. 7:
Pilot exhaust R12/R14
AVENTICS | ES05 | R415017129–BAL–001–AA
1 Marking below: pilot air = external
Marking above: pilot air = internal
1
1 Pilot air supply connection X14:
closed for internal pilot air, G 1/8"
2 Pilot air supply connection X12:
2
closed for internal pilot air, G 1/8"
1 Pilot air cover