10-520 Installation manual internal audio unit
Programming function
short description of the operation
Ring-can-come-in function
If someone rings the doorbell, the door automatically
opens. The green LED lights up if activated.
Call diversion
If someone rings the doorbell, the door
automatically opens. The green LED lights up
if activated.
Internal call
to another internal unit
Control function 8 (standard)
For the control of a gate via relay 10-831.
Floor door-opener function
After a call via the floor-bell push button, the door-
opener button opens the door of the apartment
for 30 s. Program control function 11 on a relay
(10-830, 10-836 or 10-837) that can open the
apartment door.
Activating a parallel call
The device rings in unison with another internal
unit.
36
Step 2 (within 8s.):
Press for 8s. until you hear the con-
firmation tone and the green LED
flashes.
OR
Internal unit that must be called.
OR
Internal unit that must be called.
OR
Internal unit (=MASTER) with which the
device must function in parallel.
Step 3 (within 8s.):
Press briefly until you hear
the confirmation tone and
the green LED goes out.