Herunterladen Inhalt Inhalt Diese Seite drucken

Niko 10-520 Installationsanleitung Seite 32

Vorschau ausblenden Andere Handbücher für 10-520:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

10-520 Installation manual internal audio unit
3. INSTALLATION
Cabling
The diameter of the conductors determines the maximum distance that can be bridged. The table below
shows an overview of the max. distance (from power supply to internal or external unit) per cable type.
The max. distance can be doubled by using 2 pair together.
Diameter
(e.g. UTP CAT. 5E)
Max.
distance
2- or 3-wire cabling
For small systems with 1 external
unit, the installation can be wired with
a 2-wire (a and b) cable. Use 3-wire
cabling (a, b and P for extra power
supply) in all other cases. With 2-wire
cabling, a max. of 2 can be called at
one time; with 3-wire, a max. of 4.
Mounting
1.
32
0.5mm
100m
Power supply
10-801
10-802
10-801 + 10-805-01
10-802 + 10-805-01
0.6mm
(e.g. TPVF)
150m
Max # 10-520
6
24
60
180
0.8mm
(e.g. SVV, TVVF,JYSTY...)
250m
Cabling
2-wire
2-wire
3-wire
3-wire
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis