Surrounding aperture
The insert is constructed in a way that makes it possible to make the brickwork shut almost tight around the insert
the first 10 cm in the depth from the front. This means that the hole in the front brickwork must be 54-55 cm high
and 58.5-59 cm wide. After the first 10 cm in the depth there must be 2.5 cm air space around the insert which
gives a minimum total width of 63.5 cm. and a total depth of minimum 49 cm in the hole. It is very important to
ensure the 2.5 cm air space around the insert and that the installation is correct (see point 2.2); otherwise the
fireplace insert will not cool down sufficiently. A correct cooling is crucial for the energy efficiency as well as for the
function of the Aduro-tronic.
The front of the insert with the frame covers an area of 57.4 cm in height and 63.5 cm in width.
When making the whole in the brickwork then please also remember that you might need some extra space when
the pipe has to be mounted.
2.1 Position of the fireplace insert/distance requirements
The new fireplace insert must be installed in a suitable and physically possible position. You need to be sure that
the position complies with local regulations. Distance requirements will only apply if the fireplace insert is to be
placed close to flammable materials. See below.
Distance to flammable material
Behind the fireplace
insert
25 cm
It is possible to reduce the distance to flammable material by insulating with at least 5.0 cm insulation with identical
properties to Aduro Superisol, Isolrath 1000 or similar material around the Aduro 5-1. Please make very sure that
there is still at least a 2.5 cm space around the Aduro 5-1. This means that the distance to flammable material can
be reduced to 7.5 cm (2.5 cm space around the insert + 5 cm insulation).
To the sides of the
fireplace insert
30 cm
Behind stove
30
- 15 -
To furniture
above floor level
110 cm
25
30
110
Minimum height
26 cm