3.5 ALARMS COUNT PROGRAMMING

This function allows programming a max number of 5 alarms within 24h, or allows
excluding the count, namely upon every block absence, an alarm will be
generated.
An alarm is taken into account only if its length is more than 24 seconds.
The count is reset upon every system deactivation or every 24h
NOTE: if the option of 5 alarms within 24h is chosen, the TC connection is
mandatory.
Programming is performed through jumper E, according to the table.

3.6 SCAFFOLDS FUNCTION PROGRAMMING

This function activates the flash blinking (one blink every 2.5 s) with active system
(namely when the signal is not present on terminal TC).
NOTE: if the scaffolds function is enabled, the TC connection is mandatory.
By activating such function, there is not the alarm memory any more.
WARNING: under low battery conditions, the flash blinking is deactivated, in order
to save the remaining charge.
Programming is performed through jumper F, according to the table.

3.7 SOUND MODE PROGRAMMING

The siren is able to generate 16 different sound
modes, programmable through jumpers G, H, I and L.
It is possible to chose the type of sound by starting a
listening "DEMO" phase (at reduced power) of all 16
modes.
In order to start the demonstration, connect the battery
(with BL and TC not connected) and short-circuit for an
instant the "TEST" jumper: the listening sequence will
be obtained for the 16 modes (4 seconds for each
mode, 1.5 - second interval between a mode and
another).
Sequentially count the type of generated sound, refer
to the table below for configuring the siren.
Example: if, when listening to the mode DEMO, the
th
12
one has been chosen, refer to the table in position
12 to know which jumpers must be cut to obtain such
type of sound.
Please refer to local laws in force in your country in order to verify the complying with indoor / outdoor
installations.
G
H
I
1
2
3
4
5
6
7
8
27/44
E
Alarms Count
Disabled
Enabled
F
Scaffolds Function
Disabled
Enabled
L
G
H
9
10
11
12
13
14
15
16
HPA702L-LG/N
I
L

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hpa702nHpa702lg

Inhaltsverzeichnis