3.0 SIREN MODULE

Supply positive
+
Supply negative
-
Alarm block input. Programmable NC or balanced (6K8 – 5%) referred to positive or negative
BL
System status input. Programmable NC or balanced (6K8 – 5%) referred to positive or
TC
negative
TA
TAMPER contact output terminals (normally closed)
TA
Failure output: normally supplies a positive which is lacking in case of fault
F
Data line for protecting module
D
Positive available for protecting module supply (if present) and flashlight module
+P
Flash LED command
L
System status LED command
L1
Failure status LED command
L2
Positive battery (connected at the factory)
+B
Negative battery (connected at the factory)
-B
AP
Horn connecting terminals (connected at the factory)
AP
Use screened multipole cable for burglar alarm systems.