Sunshower PURE XL series Installationshandbuch Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1
2
4
1
DRY AREA
2
BATHROOM
3
OUTSIDE
4
SHOWER AREA
PREPARATION
VENTILATION
3
A
PAGE 9
PREFERRED
B
PAGE 10
B
PAGE 10
-
-
NOT POSSIBLE
INSTALLATION MANUAL PURE XL | PART 1 | P1628 REV A
INSTRUCTIONS
GENERAL VENTILATION
GUIDELINES:
All Sunshower appliances must
be installed with ventilation
ducts
Ventilation feed and exhaust
can both be a maximum of 3 m
The space from which/to which
ventilation is provided must be
at least 12 m
3
The ducts can be of any
material, with dimensions Ø100
mm or 110 * 55 mm
Make as few bends as possible
in the ducts
The Sunshower may not be
connected to an existing
ventilation system
NON-RETURN VALVES:
Non-return valves must be installed
if the air for your Sunshower is
extracted from a humid area, e.g.
from the outside or from the
bathroom. Please refer to the
image and subsequent pages for
instructions. The non-return valves
can be ordered additionally (as a
set with the glass panels) or can
be purchased separately at your
hardware store.
Examples of humid areas:
bathroom, outside.
Examples of dry areas:
bedroom, hallway, toilet.
RECTANGULAR
ROUND NON-
NON-RETURN
RETURN VALVE
VALVE
8