Electrical
Transformer input voltage................................100 to 240 VAC, 50/60 Hz, 0.8A, class II, IP 20
Transformer output voltag ...............................12 VDC
Softener max. power consumption ..................30.7 W
Protection rating...............................................IP 20
Transient overvoltages .....................................within the limits of category II
Pollution Degree...............................................3
Temporary overvoltages must be limited in duration and in frequency.
3.2.

Outline drawing

Foleo 10 and 15L models
Foleo 20 and 30L models
3.3.
Softener's available options
3.3.1. Mixing device
The softener can be equipped with a mixing device whose function is to regulate the hardness of the water at the outlet. The
mixing can be set from 0% to 50% of hard water (i.e. 0 turn = 0% of hard water with 100% of treated water and 1-½ turn = 50%
of hard water with 50% of treated water).