When bain-marie tank is properly fi lled with water, control panel diodes should not be illuminated at all.
4

Fig.8 Bain-marie tank

1 - Alarm level sensor – very low level of fl uid in the tank (red diode signal), when fl uid level falls below this sensor sound alarm
is activated and heating function is simultaneously inactivated
2 - Optimum fl uid level sensor (green diode shall illuminate when fl uid falls below this level)
3 – Minimum fl uid level sensor (red diode is illuminated)
4 – Water temperature sensor
5 – Tank water outlet hole

4.2. Temperature regulation

Bain-marie is equipped with mechanical temperature regulator. Temperature sensor is located in the bain-marie tank
Fig.7/4 (p.11). We set the desired water temperature in the tank Fig.6/6 (p.10) with the help of regulating knob by
turning it and setting in proper position. Turning the knob clockwise increases the set temperature, and turning it in the
opposite direction causes the decrease of temperature. Turning the knob left; until it reaches the fi nal position turns
off the heaters, despite the fact that the power supply is activated.

4.3. Lamp system

The lamp system includes ceramic infrared radiators and bulbs aimed to operate in high temperatures.
Infrared radiators are used for additional, superfi cial dish heating. They use the phenomenon of temperature radia-
tion, aiming in absorbing and changing the radiation energy falling on heated dishes into heat. Radiated waves fall
through air without any diffi culties and do not emit heat until they reach the heated surface.
Bulbs and infrared radiators may be turned on/ turned off independently with switches placed on control panel Fig.6/2;
3 (p.10).

Fig.9 Bain-marie lamp system

1- Ceramic infrared radiators 250W/230V
3- 40W bulb (E27; P45 bulb shape; max working
temperature of up to 300ºC)

5. MAINTENANCE

5.1. Cleaning and maintenance

All maintenance services need to be performed after disconnecting the device from power supply!
Protect electric installation against any damage or water spillage
Do not use water stream to clean the device, only a wet cloth
Do not use any sharp objects to remove dirt!
Devices with wheels cannot be used on uneven surfaces!