PROBLEMS, CAUSES AND REMEDIES
- If it is not possible to restore the correct operation of the valve following the instructions given in the table below,
consult a skilled technician.
Problem
When the electrical circuit is
powered, the valve does not
work.
The valve works but there is no
pressure in the hydraulic circuit.
Dripping in the hydraulic
connection points
UNPACKING
The valve is supplied ready for installation. Make sure the
valve is complete and intact.

INSTALLATION

The valve is to be installed upstream from the cut-off valves
to be controlled.
All the accessories mentioned hereafter and required
to install the valves correctly are to be ordered
separately with reference to the product catalogue
of Geoline.
The choice of the inlet/outlet/discharge fittings is to be
made based on the flow rate at which the equipment on
which the valve is installed must work. The complete range
of these fittings is given in the product catalogue of Geoline.
ATTACHMENT
Secure the general valve using the dedicated holes in the
attachment brackets.
10
FIRST PART
Probable cause
Electricity is not reaching the motor.
The protection fuse of the electrical
circuit has blown.
The hydraulic inlet pipe is obstructed.
Maximum pressure too low.
VOLUMETRIC valve open (if installed
in circuit)
Pressure of delivery liquid too low
Nozzle cross section too large or
nozzles too noisy.
Compensation cocks of the cut-off
valves completely open
Blocking fork of fittings not inserted
correctly.
SECOND PART
I n s t r u c t i o n
(reserved for skilled technicians)
ELECTRICAL CONNECTION (FIG. 5)
- Make sure the supply from the electrical system complies
with the values stated in the TECHNICAL DATA table.
Voltages that vary from this range could cause problems
and could damage the electrical circuit.
- Protect the electrical supply circuit by means of a suit-
able fuse.
- The electrical connection must be made in accordance
with regulations in force in the country in which the valve
is used.
- When the battery is flat and the alternator is worn, there
may be peaks in the voltage that could cause damage to
the electrical circuit. Always keep the state of the battery
and the alternator under control.
- Remove the connection pin protection cap.
- Ensure the plug on the power supply cable is fitted with
a sleeve and insert it in the motor socket (fig.5).
- The minimum cross section of the valve cables must
be 0,75 mm².
m a n u a l
Remedy
Make sure the plug is fitted properly in
the connector.
Make sure the control panel in use is
working correctly.
Check the condition of the fuse and
replace it if necessary.
Check if the inlet pipe is clear. If
present, clean the inlet filter carefully.
Increase the maximum pressure, by
turning the pressure adjustment knob.
Use dedicated switch on the electrical
control panel to increase the pressure.
Check if the delivery pump is working
efficiently.
Check if the flow rate of all the utilities
complies with the technical data of the
operating machine.
Shut-off the compensation cocks
Insert the blocking fork correctly.
6
ENG