the device can fall if the primary attachment fails.
Make sure that the safety cables can carry 10 times the weight of the device. Make sure that the
maximum height of drop is limited so that no injuries can occur. If the safety cables are long, wrap
them around the truss multiple times to reduce the height of drop to a safe level.
Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
Make sure there is no flammable material within a 0.5 m radius of the device.
7.
Connection
Power
Connect the device to the mains with the power plug.
Power all devices directly off a grounded switched circuit.
Do not connect the device to a rheostat or dimmer circuit, even when using the rheostat or dimmer
channel solely for 0 % to 100 % switching.
Have a qualified electrician carry out the electric connection.
DMX-512 Connection
When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the
other side to the male XLR input of the device. Multiple devices can be linked through serial linking.
The linking cable shall be a dual core, screened cable with XLR input and output connectors.
A DMX terminator is recommended for installations where the DMX cable has to run a long distance
or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the
digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω
resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in
the chain.
8.

Operation

8.1

Control Panel

Access the control panel functions using the four buttons below the display.
button
function
MENU
to access the menu, quit the current function without saving the setting, or quit the menu
UP
to scroll upward in a list of functions or options, or increase a value
DOWN
to scroll downward in a list of functions or options, or decrease a value
ENTER
to confirm and save a selected option or value
8.2
Menu
menu
options
Addr
SLNd
MASt/SL1-SL4
ShNd
Stob
dIMM
Led
hour
8.3

Stand-Alone Mode

The device starts running in stand-alone mode after connection to the mains. This mode allows you to
use the device without controller.
1.
Connect the device to the mains to switch it on
2.
Press MENU to enter the menu.
3.
Navigate to <ShNd> or <Stob> with UP or DOWN and press ENTER to confirm.
4.
Select an option with UP or DOWN and press ENTER to confirm.
5.
Navigate to <dIMM> with UP or DOWN and press ENTER to confirm.
6.
Select a dimmer level from 0 to 255 and press ENTER to confirm.
V. 01 – 06/05/2015
VDPL2000STN
function
DMX address from A001-A512
master/slave mode selection
strobe effect with sound control from SH0-SH6
strobe from 0-255
dimmer from 0-255
display on-off
fixture operation time
5
©Velleman nv