ADVICE AND CHECKS

IMPORTANT:
- The installation of this device must be carried out by specialized technicians.
- In case of battery charger's misuse, the guarantee falls off and the manufacturer
declines all responsibility for damages to people and things.
- Do not carry out any maintenance when the battery charger is connected to the
230V power supply net.

BATTERY CHARGER

- Install the battery charger in a dedicated room, dry and ventilated; fix it in a proper way.
- Do not cover air intakes and assure an appropriate ventilation.
- Before disconnecting the battery charger from 230V power supply, turn the security switch off.
CABLES
- Use cables with appropriate section, minimum cross section area 4 mm².
- Protect cables from any possible damage.
SPECIFIC ATIONS
Mains input voltage
Max. power
Charge current
- nominal
- arithmetic
Current control
Consumption (no connected mains)
Automatic control of charge cycles
- Max charge
- Maintenance
Commutator for battery choice (Pb or Gel)
Charge system
Length of 14,4V end-charge phase
- Lead type battery
- Standing type battery
Overload protected
Overtemperature protected
Inversion polarity protection
Security on/off switch
12V fuse
230V fuse
Charge signalled by LED
230V connection
Battery connection
Mains signal connection
Anodized aluminium case
Dimensions (mm)
Weight (Kg)
Always provided
230 Vac 50 Hz / 12Vdc
5
A920
300 VA
18 A
15 A
0,3 mA
25°C
14,4V
13,8V
Buffer battery
20 min.
380 min.
car type 25A
internal 3,15A
Schuko plug
Terminals 6,3
Terminals 6,3
170 x 220 H130
5,5