Herunterladen Inhalt Inhalt Diese Seite drucken

jbc ADVANCED-Serie Bedienungsanleitung Seite 24

Rework station
Vorschau ausblenden Andere Handbücher für ADVANCED-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71
HOT TWEEZERS PA 4200
For hot tweezers to work properly, the following
components are required:
- Control unit.
- Hot tweezers PA 4200 ref. 4200000. For general
desoldering and soldering work in professional
electronics.
Power: 100W.
Effective power per cartridge fitted: 50W.
- Stand PA 8120 ref. 0748120.
- A set of cartridges (see range).
Changing the cartridge
To extract the cartridge the screw needs to be
unfastened and the cartridge pulled out. Insert
the new cartridge and push it thoroughly. Then
check that both tips of the tweezers coincide
and screw it.
Important.
-
It is essential to insert the cartridge till the end
for a good connection. Take the mark
reference and check that both parts of the
tweezer coincide.
Alignment
Screw
Ref. 0780841
as
RANGE OF CARTRIDGES
PA 4200 has an individual temperature control
for each cartridge so it is supplied
individually.
ØA
PATENT PENDING
JBC reserves the right to make technical changes without
prior notification.
23
ENGLISH
Chip components
Ref.
A mm
2245-271
1,5
2245-272
2,5
A
Dual in line IC
Ref.
A mm
2245-273
4,0
2245-274
6,0
2245-275
8,0
2245-276
10,0
A
2245-277
15,0
2245-278
20,0
QFP and PLCC
Ref.
A mm
2245-279
A
2245-280
11,0
A
Cable stripper
Ref.
A mm
2245-281
3,5 max
2245-282
2245-282
2245-281
8,0