TABLE II: GAS TECHNICAL DATA, PRESSURE, BIG BURNER NOZZLES (7 KW), AND MINIMUM
SCREW
Nation
Cat.
and
NOZZLE
category
ENG, ICEL, DENIM,
FIN, SWED, PORT,
2H
GREECE, IRELAND
NETHERLANDS
2L
ICEL, DENMARK,
3B/P
FINLAND,
SWEDEND
GREECE
3+
ENGLAND
NORWAY
3P
IRELAND,
3P
PORTUGAL
3P
NETHERLAND
(1) Including the pilot thermal capacity approx. 400W.
R.o.A. = Regulation of primary air
TABLE II: GAS TECHNICAL DATA, PRESSURE, BBRV BURNER NOZZLES AND MINIMUM SCREW
Nation
Cat.
and
NOZZLE
category
ENG, ICEL, DENIM,
FIN, SWED, PORT,
2H
GREECE, IRELAND
NETHERLANDS
2L
ICEL, DENMARK,
3B/P
FINLAND,
SWEDEND
GREECE
3+
ENGLAND
NORWAY
3P
IRELAND,
3P
PORTUGAL
NETHERLAND
3P
(1) Including the pilot thermal capacity approx. 400W.
R.o.A. = Regulation of primary air
GB
Type of
GAS PRESSURE
gas
UPSTREAM mbar
Ø mm. Type
Nom. Min. Max.
G20
20
17
25
G25
25
20
30
G30*
28
25
35
G31
29
30
G30*
29
20
35
G31
37
25
45
G31
30
20
35
G31
37
25
45
G31
50
42,5
57,5
Type of
GAS PRESSURE
gas
UPSTREAM mbar
Ø mm. Type
Nom. Min. Max.
G20
20
17
25
G25
25
20
30
G30*
28
25
35
G31
29
30
29
20
35
G30*
G31
37
25
45
G31
30
20
35
G31
37
25
45
G31
50
42,5
57,5
BURNER
BY-PASS
fast
R.d.A.
Ø mm.
MARKED
X mm.
MARKED
115/170
195 K
31
-
130 R
63
121/250
210 L
40
-
130 R
63
130 K
31
85
84
-
44
130 K
84
31
-
85
44
140 K
91
31
-
85
44
130 K
84
31
-
44
85
77/170
125 K
31
-
80
38
Nozzle marking Ø 1/100
F = Fixed
BURNER
BY-PASS
fast
R.d.A.
Ø mm.
MARKED
X mm.
MARKED
115/170
255 K
F
-
180
63
121/250
265 K
F
-
180
63
175 K
F
110
84
-
44
175 K
84
F
-
110
44
185 K
91
F
-
110
44
175 K
84
F
-
110
44
77/170
160 K
F
-
100
38
Nozzle marking Ø 1/100
F = Fixed
- 16 -
PILOT
Gas
Nominal
1 way
pressure
Thermal
at the nozzle
kW (1)
Max.
Min.
MARKED
100%
mbar
mbar
20 R
-
19,2
-
2,6
-
7,0
2,7
20 R
-
23,8
-
3
-
7,0
2,7
20
28,9
3
7,0
-
-
-
2,7
20
-
28,9
-
3
-
2,7
7,0
36,8
5,4
20
-
29,8
-
3,8
-
7,0
2,7
20
-
36,8
-
5,4
-
7,0
2,7
20
-
49,8
-
6,7
-
7,0
2,7
PILOT
Gas
Nominal
1 way
pressure
Thermal
at the nozzle
kW (1)
Max.
Min.
MARKED
100%
mbar
mbar
36
-
19,0
-
2,85
-
12,0
2,7
36
-
23,4
-
3,3
-
12,0
2,7
19
28,8
3,8
12,0
-
-
-
2,7
19
-
28,8
-
3,8
-
12,0
2,7
37,7
4,8
19
-
29,8
-
4,3
-
12,0
2,7
19
-
36,7
-
4,8
-
12,0
2,7
19
-
49,8
-
7,2
-
2,7
12
gas
concumption
15°C- 1013
P.T.
l/h
g/h
Min
2,6
55
741
286
-
-
2,6
52
332
862
-
-
2,6
217
84
213
551
7
250
479
97
184
2,6
7
217
84
213
551
284
110
210
544
2,6
6
284
110
544
210
2,6
7
284
110
210
544
2,6
6
284
110
544
210
gas
concumption
15°C- 1013
P.T.
l/h
g/h
Min
4,56
55
1270
286
-
-
4,56
52
1477
332
-
-
4,56
371
84
945
213
7
428
820
97
184
4,56
7
371
84
213
945
486
110
932
210
4,56
6
486
110
932
210
4,56
7
486
110
210
932
4,56
6
486
110
210
932