Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTRUCTION
EN
PAW-HPMED
i
Read this instruction before installation
and wiring of the product
Graphic touch display
PAW-HPMED is an external display with an internal room tempera-
ture sensor for connection to a PAW-HPM. PAW-HPMED permits
changing operation mode, setting party mode, adjusting setpoints and
timers and viewing alarms. The display is connected to the external
display port of the PAW-HPM.
Technical data
Protection class
IP30
Power supply
24V DC via external diplay port of the
PAW-HPM
Power consumption
50 mA
Connection cable
Twisted-pair, 0.25 mm
Display
TFT-LCD (resistive)
Backlight
LED (backlit)
Language
German, English, French, Spanish
or Italian, set automatically depending on
the language used in the PAW-HPM
Aspect ratio
4:3
Resolution
320 x 240
Dimensions (WxHxD)
120 x 90 x 27 mm

Installation

PAW-HPMED is mounted on a wall using the supplied wall bracket. It
can also be mounted on a device box (cc 60 mm). The display can be
removed from the bracket if necessary.

Operation

The following information is displayed on the PAW-HPMED start page:
Settings
Heating
circuit 1
Domestic
hot water
Figure 1. The start page
The mode switch menu permits setting the value of the PAW-HPM mode
switch:
Automatic
Off
Figure 2. The Mode switch page
2
Alarm
The mode
switch menu
Heating circuit 2
Heat producer
Holiday
Cooling
Summer
Duration
PAW-HPMED
Heating circuits
Domestic hot water
Off
Off: Valve stays in
Off: Valve stays in cur-
current position,
rent position, pump off
pump off
Auto-
Automatic operation: Automatic setpoint switch-
matic
ing depending on timer program (day/night)
Summer
Switch-off operation:
Automatic operation:
Valve closed, Pump
Automatic setpoint
off, Frost protection
switch depending on
remains active
timer program
Holiday
Reduced operation/support operation: Setpoints
of non-operating time NO (night) apply
Duration
Nominal operation: Setpoints of operating time
1 OT1 day apply
Cooling
Automatic cooling
Automatic operation:
operation
Automatic setpoint
switch depending on
timer program
Alarm
Visible if there are any alarms from the PAW-HPM.
Settings
This page is divided into controller and display settings. The display
settings page is used to set the elapsed time before the display pow-
ers down to a dimmed light level, as well as what brightness the lower
light level should use.
The controller settings page is used to show information about the
controller and for setting time and date of the system clock. Changes
are made by pressing the relevant line.
The program page permits setting and reading different values:
Current
setpoint
Current
mode
Timer
Temperature
Figure 3. The program page
Heat
producer
Off
Automatic
operation:
Setpoint
according to
demand
Setpoint increase
and decrease
Party mode

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis