Herunterladen Inhalt Inhalt Diese Seite drucken

Olimpia splendid Sherpa OS-CEBCH48EI Handbuch Für Installation, Gebrauch Und Wartung Seite 55

Vorschau ausblenden Andere Handbücher für Sherpa OS-CEBCH48EI:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameter
DOMESTIC WATER
PRODUCTION
0
production disabled
1
production activated via
free contact
2
production activated via
domestic water tank sensor
ANTI-LEGIONELLA C CLE
FUNCTION MODE
0
Internal unit heat pump
+ electrical heater elements
1
electrical heater
elements in domestic water
tank
ANTI-LEGIONELLA
FUNCTION FREQUENC
Ldi 0 function disabled
If lda 1 and Ldi>0 the
function is enabled with the
electrical heater element in
the domestic water tank
ANTI-LEGIONELLA C CLE
ACTIVATION TIME
ANTI-LEGIONELLA C CLE
TEMPERATURE
ANTI-LEGIONELLA C CLE
DURATION
PUMP FORCED
ACTIVATION
0
pump forcing not
activated
1
pump forcing activated
INTERNAL UNIT
ELECTRICAL HEATER
ELEMENTS ACTIVATION
DELA
PUMP ACTIVATION
FREQUENC WHEN SET-
POINT IS REACHED
DOMESTIC WATER
TAN TEMPERATURE
H STERESIS T3
DISPLAY
MENU
MNEMONIC
dhU
Service
LdA
Service
Ldi
Service
Lds
Service
Ldt
Service
Ldd
Service
FPA
Service
EhP
Service
cPP
Service
hyS
Service
Range of
Factory
ad ustment
setting
0,1,2
1
0,1
0
0 - 30 days
0
00,0 - 23,5
2,00
50°C - 80°C
65°C
0 - 240
30
minutes
0,1
0
0 - 60
15
minutes
0-20 minutes
0
5°C - 25°C
10°C
COMMENTS
If dhU 1 set the
external thermostat
(free contact) to a
temperature below
60°C
Decimals
tens of
minutes, e.g.: 0.1 10
minutes up to 0.5 50
minutes
Function active solely
with system in stand-by
Delay between starting
the heat pump and
checking the conditions
for activating stage 1
of the electrical heater
element. If enabled,
the second stage
is activated with a
15-minute delay after
the rst ( xed time)
When the set-point is
reached (compressor
off):
cPP 0: pump stays on
cPP>0 pump switches
off for cPP minutes,
then switches on
for one minute; this
sampling is performed
in a cycle to verify the
temperature of the
water in the circuit
To be used solely when
dhU 2 (sensor t3 in
domestic water tank)
55
3