Herunterladen Inhalt Inhalt Diese Seite drucken

Ex-Data; Nec; Atex; Iecex - Ecom Tab-Ex 01 DZ1 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22

5. Ex-Data

5.1 NEC

CSA Certificate no.:
Ex-Marking:
Ambient temperature:
Approved for Division 1 and 2 Class I, II and III
Approved for Zone 1 and 21, IIC and IIIC

5.2 ATEX

ATEX Certificate of Conformity no.: Sira 15ATEX1205X
Ex-Marking:
Ambient temperature: -20 °C ≤ Ta ≤ +50°C
Approved for zone 1 and 2, device group II, explosion group IIC (explosive gases,
vapors or mist), temperature class T5.
Approved for zone 21 and 22, device group III, explosion group IIIC (combustible
flying, non-conductive dust and conductive dust), maximum Temperature 100°C.

5.3 IECEx

IECEx Certificate of Conformity no.: IECEx SIR 15.0075X
Ex-Marking:
Ambient temperature: -20 °C ≤ Ta ≤ +50°C
Approved for zone 1 and 2, device group II, explosion group IIC (explosive gases,
vapors or mist), temperature class T5.
Approved for zone 21 and 22, device group III, explosion group IIIC (combustible
flying, non-conductive dust and conductive dust), maximum Temperature 100°C.
6
70024080
Class I, II and III, Div 1 Groups A-G T5
Class I, Zone 1 IIC T5
Zone 21 IIIC T100°C
-20 °C ≤ Ta ≤ +50 °C
† II 2G Ex db ia op is IIC T5 Gb
† II 2D Ex tb IIIC T100°C Db
Ex db ia op is IIC T5 Gb
Ex tb IIIC T100°C Db

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis