9.2 AIR-COOLED MODELS (Fig. 7)

For air-cooled models, it is very important to keep the finned condenser and its external filter (if any) clean. Have
the finned condenser cleaned at least once every two months by an Authorized Technical Service Centre, which
can include this operation in the scheduled maintenance program.
The external filter (if any) must be cleaned at least once a month, as follows:
Switch off appliance and cut off power supply with the switch (7 in Fig. 4) fitted at the installation stage.
Open plastic grille.
Remove filter and keep it at a distance from the appliance.
Remove dust from filter by blowing with compressed air.
Replace filter in its seat and close plastic grille.

9.3 CLEANING AND SANITIZING OPERATIONS

A cleaning and sanitizing kit specifically designed for this appliance is available from your dealer.
‼ Do not use corrosive substances to remove limescale from the appliance, because this will invalidate the
warranty, and may cause serious damage to the materials and components of the appliance.
Do not use jets of water to clean the appliance.
‼ All cleaning operations must be carried out only after the electric power and water supplies have been
disconnected, as described previously, by professionally qualified and authorized personnel.
Follow the instructions given in the cleaning and sanitizing manual supplied with the appliance.
‼ IMPORTANT:
All the ice produced during the first 30 minutes after cleaning and sanitising operations, together with any ice
present in the bin, must be discarded.
Complete sanitizing can only be carried out only by the Authorized Technical Service Centres, and must be done
regularly depending on the conditions of use of the appliance, the chemical and physical features of the water,
and after every period in which the appliance has remained at a standstill for any length of time.
You are advised to ask your dealer to draw up a scheduled maintenance contract that will cover the following:
Cleaning the condenser
Cleaning the filter located on the water supply solenoid valve
Cleaning the ice container
Checking the charge of coolant gas
Checking the operating cycle
Sanitizing the appliance

10 PERIODS AT A STANDSTILL

If you do not intend to use the appliance for a certain period of time, proceed as follows:
Switch off the electric power source by means of the switch (7 in Fig. 4), and remove the plug of the appliance
from its socket (if any)
Shut off the water supply by turning off the water supply tap (8 in Fig. 4)
Carry out all the operations envisaged for scheduled maintenance of the appliance (see chapter 9)
Clean filter of water supply solenoid valve as described in chapter 9.1
Clean filter of air condenser (if any) as described in chapter 9.2
12