7 MAIN CAUSES OF OPERATING FAILURE

Should the appliance fail to produce ice, before calling on the Authorized Technical Service Centre, first check
carefully that:
The water supply tap (8 in Fig. 4), fitted during the installation phase, has been turned on.
Electric power is reaching the appliance; the plug (if any) is properly inserted in the socket, the switch (7 in
Fig. 4) is in the "ON" position, and the push button (13 in Fig. 3) is lighted up.
Furthermore:
If there is excessive noise, make sure that the appliance is not touching furniture or sheet metal which can
give rise to noise or vibrations.
Should any trace of water appear, check the drain hole of the container to ensure that it is not clogged, that
the water fill and drain pipes are correctly connected and are not throttled or damaged.
Make sure that the temperature of the air or water does not exceed the installation limit values (see
paragraph 5.2).
Make sure that the water inlet filter is not clogged (see paragraph 9.1).
If the fault still persists after the above inspections have been made, turn off the electric power source by means
of the switch fitted during the installation phase, pull out the plug from its socket, turn off the tap connecting
the appliance to the water mains, and contact the nearest Authorized Technical Service Centre.
To obtain a faster and more efficient reply when you call the Centre, state the model of the appliance precisely,
together with its serial number or manufacturing number. This information is given on the serial N° plate (Fig. 1)
affixed to the rear of the appliance and on the cover of this manual.

8 OPERATION

The appliance has a thermostat probe in the ice bin, which stops ice production when the ice accumulated in the
bin reaches the probe connected to the thermostat. When ice is taken from the bin, the thermostat will
automatically reactivate ice production, thus creating a new supply of ice.

9 MAINTENANCE

9.1 CLEANING THE FILTER OF WATER SUPPLY SOLENOID VALVE (Fig. 6)

All the operations described in this paragraph must be carried out only after the electric power and water
supplies have been disconnected, as described previously, by professionally qualified and authorized
personnel.
!! At least every two months, clean the filter (14) located on the water inlet solenoid valve, proceeding as follows:
Switch off the electric power supply by means of the switch (7 in Fig. 4), fitted during installation, and
disconnect the plug of the appliance from its socket (if any).
Shut off the water supply by turning the tap (8 in Fig. 4) fitted during installation.
Unscrew the threaded ring nut (11) of the water feed hose, located at the outlet of the solenoid valve at the
rear of the appliance.
Using a pair of pliers, remove the filter (14) from its seat without damaging the water feed pipe connector.
Place the filter under a strong jet of water to remove residue, but replace the filter if it is excessively dirty.
After having carried out the cleaning operations, refit the filter and hose pipe taking the necessary precautions
described earlier in the manual.
When the operations have terminated, turn on both the electricity supply and water supply.