Troubleshooting

q Operation
p
Symptom
No power
Cannot operate
( common to
wireless remote
controller, HD Visual
Communication Unit)
Cannot operate using
the wireless remote
controller
Cause and remedial action
p p Is the AC adapter securely connected to the AC outlet?
p p Is the power plug of the AC adapter connected properly?
p p When the unit is being operated by the wireless remote controller
 Also refer to the "Cannot operate using the wireless remote
controller" item.
p p Is the power on?
 If the unit's status display lamp is off or if it has lighted up orange,
it means that the unit's power is not being supplied.
p p Has the correct unit to be operated been selected?
p p Have the remote control's batteries run down or have the batteries
been installed with their polarities reversed?
 If the status display lamp does not blink even when the wireless
remote controller is operated near the wireless remote controller
signal light-sensing area, it means that the batteries have run down.
Replace the batteries.
p p Is there a fluorescent light or plasma monitor near the unit and,
if so, is the wireless remote controller signal light-sensing area
exposed to its light?