1
GENERAL
is a WC equipped with a pump/macerator
®
which installed and used correctly will give reliable and
SANIMARIN
consistent service for many years. SANIMARIN
or mobil unit use. Please follow these installation
instructions, paying attention to the following warnings;
"
" Possible danger to personnel,
"
" Warning of possible electrical hazard,
"
" Possible danger of damage to the macerator.
WARNING
APPLICATION
uses an electronic programmer which
®
operates as follows;
SANIMARIN
• STANDARD Operation: press the NORMAL pad on the
control console. Cycle time 19 secs.
Water consumption: 2.2 lit.
• ECO Cycle: press the ECO pad on the control console.
Cycle time 10 secs.
Water consumption: 1.2 lit.
• DRAINING Cycle: press the EMPTY pad on the control
console.
2
LIST OF ACCESSORIES INCLUDED
Tools required to fit a SANIMARIN
• A drill with a set of 4 mm to 8 mm drill bits
• A hole saw 57 mm in diameter
• A hole saw 28 mm in diameter
• A reversible screw gun
• Flat blade and cross-tip screwdrivers
• A 10 mm box spanner
(see drawing n° 3 page 2)
3
DIMENSIONS
4

TECHNICAL DATA

Applications
Max. vertical evacuation
Max. horizontal evacuation
Nominal power
Electrical class
Isolation level
Net weight
SANIMARIN
SANIMARIN
SANIMARIN
SANIMARIN
SANIMARIN
This product should not be used for any other
purpose other than that described here. The minimum
CAUTION :
discharge pipe inner diameter should be 19mm.
5
PERFORMANCE CURVE
6
INSTALLATION GUIDE
6a
FIXING BOWL TO THE FLOOR
a – Draw the outline of the base on the floor, in the area
around the fixing holes in the ceramic bowl.
b – Measure 15 mm from the outline drawn, position the
brackets
and drill through the middle of the holes.
c – Screw the brackets in place, leaving them loose, they
A
will be tightened once the bowl has been fitted.
d – Fit the bowl.
is for marine
®
(see drawing n° 2)
®
discharge of a WC
3 m
30 m
320 W in 12 V version
400 W in 24 V version
IPX4
III
17,5 Kg
®
21 Kg
31
®
24,5 Kg
35
®
26.5 Kg
48
®
Bidet 35 21 Kg
Elite
®
(see drawing n° 5 page 2)
Note: wait until all the connections have been made
before fixing the bowl definitively in place.
Note: on the SANIMARIN
the front. The two screws at the back are placed vertically.
6b
CONNECTING THE WASTE PIPE AND THE WATER
SUPPLY PIPE
Connect the 38/38 mm diameter bend
and the waste pipe, and then fix in place with clip
U
Water supply pipe. To be connected to a seawater
pump (supplied as an option), or to the pressurized onboard
1
freshwater system. The pressure in the system must be at
least 1.7 bar.
Note: it is possible to fit a seawater pump other than the
pump supplied as an option, provided that the current
requirement is not more than 16 A, if the pump is to be
controlled via the touchpad. There is another possible
assembly principle: that of a water supply system, in which
the pump cuts in when the pressure drops.
6c
FITTING THE CONTROL TOUCHPAD
The touchpad
and
must be fitted in a position where
it does not interfere with use of the seat and cover, and it
L
C
must not be placed more than 1.50 m (length of the
electrical wiring) from the electrical control box. Drill out
a 57 mm diameter hole and fix the holder
screws, making sure that the clips are correctly placed at
the top and the bottom. Insert the electrical wiring in the
hole. Clip the touchpad in place.
6d
FITTING THE CONTROL CONSOLE FOR THE BLACK
WATER TANK (OPTION)
Assembly similar to that of the touchpad. Connect the electrical
wiring to the connector
1
6e
ELECTRICAL CONNECTIONS
a - Fix the box
in a dry, protected location.
b - Connect the wiring from the touchpad to the box.
R
c – Fit the connector protection cover
d – Drill out a 28 mm diameter hole for the motor wiring and
the solenoid valve for the toilet
e – Insert and connect the electrical wiring from the
to the electrical box, using the sealed
connector. Lastly, connect the electrical box to the
®
SANIMARIN
battery, making sure that the cross-section of the wires is
sufficient (2.5 sq. mm up to 3 m and larger if a greater
length is required).
The electricity supply to the SANIMARIN
connected directly to the boat's electrical switchboard, and it
must be used solely for that equipment. It is advisable to add
a 25 A fuse in a 12 Volt system, and a 15 A fuse in a 24 Volt
system. Our equipment is fitted with its own safety device, a
circuit breaker located in the electrical control box. If the
circuit breaker opens, you can reset it without having to open
the electrical box (see diagram 6h - part
Make sure the wires are connected correctly:
Red wire = positive (+) terminal,
black wire = negative (-) terminal
35 , there is only one bracket, in
®
to the check valve
Q
with the four
W
on the touchpad wiring.
.
J
must be
®
).