Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71
11 - CONFIGURATION MENU (installer)
General rule
If
Set temperature comfort greater than the maximum entered lock
is
If
Set temperature t or t2 less than the minimum entered lock
is
The following rule will apply to all other temperatures:
WINTER (
) =
COMFORT temperature
SUMMER (
) =
COMFORT temperature
IMPORTANT!
During thermostat operation, the user may not set a

11. - DESCALING CYCLE

6
If the function is activated, the programmable thermostat activates every day
of the year (24h after the last intervention of the relay), for 2 minutes. It
activates the controlled device (pump, valve etc.) to prevent scaling or
jamming caused by prolonged inactivity.
The thermostat activates only if the connected load was never
switched on in the previous 24 hours.
From normal thermostat operation, press the
path
->
Set PROG
->
POMP ON
->
select the desired item:
POMP ON nO
Press
«OK»
to confirm.
Press the
Mode
key
twice
to exit.
Factory setting upon first switching on the function is disabled.
, it will level out with it.
, it will level out with it.
>
night economy temperature
<
night economy temperature
temperature Set t
higher or lower than the
Mode
key for secs. follow the
5
,
press
«OK»
and with the
(NO) or
POMP ON 2'.
>
antifreeze temperature
max and min. locks entered
keys
EN
.
/OK
or
/OK
43

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis