Herunterladen Inhalt Inhalt Diese Seite drucken

Control Panel; Manual Operation - Stienen B.E. PFB-35 Kurzanleitung

Futterwaage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CONTROL PANEL

If no indicator light up in the keys and no dosage is started the total amount of feed dosed till now is shown
on the right display (in kilogram). If a dosage is started the current silo number is shown on the left display
and the current feed hopper content is shown on the right display (in gram).
C
/
HECKING MEASURING VALUE
CHANGING SETTINGS
If a key is pressed and the light lights up continuously, a measured value or a calculated setting is shown on
the display. Press the same key again to change the corresponding setting (the light flashes).
A setting can be changed using the + and - (plus and minus) keys.
Attention! When the
CURVE
external control computer, certain settings
K
EY SEQUENCE
If a key sequence is shown you have to entered the given sequence (from left to
right) before the measured and/or set value are displayed. The lights in the
selected keys are continuously on. The light in the last selected key flashes if a
setting is selected.
A
LARM LIGHT
The
(alarm) light lights up when there is an alarm. The
S
TATUS FEED WEIGHER
If there is no feed in front of the feed sensor, the
light up. If the indicator flashes a feed sensor alarm occurs.
The empty feed weighing hopper is tared first, the
lights up during taring. If the indicator flashes a tare alarm occur.
The
silo auger is started
alarm occur.
After the silo auger has stopped, the
exactly and the supply time (for the next weighing cycle) is calculated again. If the
indicator flashes a tare alarm occur.
The
discharge hatch
is then opened. The weighing cycle starts again after the
discharge hatch has been closed. If the indicator flashes a discharge hatch alarm
occur.
is
ACTIVE
or the feed weigher is connected to an
CANNOT
be changed.
light flashes when the 'main alarm' is off.
"feed sensor
status" indicator will
"Taring weighing
hopper" indicator
after weighing hopper taring. If the indicator flashes a silo
weight
in the weighing hopper is
measured

MANUAL OPERATION

Set the 'manual operation switch' on the front to its upper position to open the discharge
hatch. The silo auger is driven when the discharge hatch is fully open, provided that the
feed sensor does not sense any feed. If the feed sensor senses feed, the feed supply is
stopped temporarily until the feed sensor no longer senses feed. If you have several silos,
you also have to operate the silo by hand (set DSR to position "1").
Manual operation sequence:
1. Manually switch on the auger and/or the feed chain.
2. Set the switch of the DSR with the required type of feed (silo) to position "1"
3. Set the manual operation switch on the PFB-35 feed weigher to the "OPEN" position.
The extra amount of feed you feed manually is NOT REGISTERED by the PFB-35. Afterwards set all
'Manual operation switches' to the 'AUTOM.' position (on the PFB-35, on the DSR modules and on
the auger and/or feed chain).
WATER
Today's current counter reading is shown on the left-hand
display (in litres)
Yesterday's counter reading is shown on the left-hand display (in
litres)
The total counter reading up to and including today is shown
using both displays. 1212432 litres is shown as follows:
If you change the "0" to "1" all water counter readings (including
the total volume) are deleted.
FEED
Current volume of feed dosed today (in kilograms)
Volume of feed dosed yesterday (in kilograms)
When the feed curve is active (day number is 1 or higher), the
left-hand display shows the calculated amount to be dosed for
the current feeding cycle.
If the feed curve is off (day number = 0), you can set the
amount of feed to be dosed for the next feeding cycle on the
right-hand display.
Note! If the feeding cycle has already started, the changed
setting will not be processed until the next feeding cycle.
You cannot change this setting if the PFB-35 feed weigher is
controlled by a control computer.
Amount of feed yet to be fed in the current feeding cycle (in
kilograms)

Quicklinks ausblenden: