24
Fault
Ice too thin or not
complete
Ice making is slow
Ice full indicator light is lit
up but there is no ice
Errot Codes
Code
E1
E2
E3
Possible Cause
Tank water level is too low
Inlet valve does not work
Not enough water
pressure
Water pipes are blocked
Condenser is dirty
Temperature too high or
the ventilation is bad
The float ball in tank is too
high or there is leakage
Water tank leakage
Inlet valve could not be
closed tightly or leakage
Not enough space around
the machine
Faulty ice tray baffle
Possible Cause
The ambient temperature sensor is defective.
The exhaust air temperature sensor is defective.
The two temperature sensors are defective.
Check the following:
Check the water level
check if there is any
leakage
Check the inlet valve
Water pressure must be at
0.13-0.55 Mpa
Check the pipes and joints
for dirt
Clean the condenser
Ambient temperature
should not exceed 40 ,
and ensure ventilation
Adjust the float ball or
replace the water tank
Replace water tank
Clean or replace the inlet
valve
Provide adequate space
Check if the ice tray baffle
is stuck

Quicklinks ausblenden: