  • DEUTSCH, seite 10
• The SR 99H must not be connected to uncleaned compressed
air.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
8. Technical data.
Particle collecting capacity
The class A3P3 filter element collects more than 99.99% of all
particles at a flow rate of 95 l/min and using paraffin oil as the test
aerosol (EN 143:2000).
Collection of gases/vapours
The class A3P3 filter element can adsorb 100–150 grams of oil
before it is saturated (EN 14387:2004).
Supply pressure
6–10 bar (600–1,000 kPa).
Air flow rate
Max. 900 l/min.
Supply pipe
The supply pipe to the compressed air filter must have an inside
diameter of at least 11 mm to ensure that it can deliver the maxi-
mum air flow rate.
Power supply to the SR 99H
Connect the filter to an earthed 220–240 V, 50 Hz, 10 Amp supply,.
Air temperature downstream of the SR 99H
At maximum heating power, the air temperature will be about 85 °C
immediately downstream of the heater unit.
Degree of protection of the SR 99H
The enclosure conforms to the provisions for IP65, which means
that the air heater can be flushed with water and is dust-tight.
Heater rating of the SR 99H
The maximum heat output is 1,750 W.
Overheating protection of the SR 99H
The overheating protection trips at around 95 °C.
Compressed air supply tube
The following tubes are type approved together with all Sundström
compressed air fed equipment.
• SR 358. 9.5/15 mm plastic tube, made of polyester reinforced
PVC. Oil and chemicals resistent. 5–30 m.
• SR 359. 9.5/18 mm rubber tube, made of EPDM/Polyester.
Antistatic, heat resistant. 5–30 m The Sundström air heater, SR
99H, must always be used with SR 359.
• SR 360. 8/12 mm plastic spiral coiled tube made of Polyurethane.
2, 4, 6 and 8 m.
9. Components. Fig. 1
SR 99
No. Description
1. Inlet -
2. Regulator with pre-collector
3. Drain bowl
4. Guard
5. Pressure gauge
6. Pre-collector element
7. Hose with couplings
8. Filter housing
9. Activated carbon
10. Particulate filter
11. Knob
12. Outlet
13. Set of seals for filter housing
14. Y coupling
15. SR 292 Filter element
16. Safety coupling female 1/2"
Compressed air tube. See 8. Technical data
SR 99H
No. Description
1. Inlet -
2. Hose with couplings
3. Nut M10
4. Heater element
5. Outlets
6. Control unit
7. Reset button
8. Presetting knob
9. Warning lamp
10. Operation indicating lamp
11. Safety coupling female
12. Nipple to safety coupling
13. Hose green 0,5m
10. Approvals
Ordering No.
R03-2601
R03-2503
R03-2502
R03-2108
R03-2504
R03-2605
-
-
-
R03-2607
-
R03-2604
R03-2127
R03-2001
R03-2103
Ordering No.
R03-2701
-
-
-
-
-
-
-
-
R03-2103
R03-0143
R03-2606
17