MWW Cutting Torch Brenner 90 - General Information
1.1
Labeling According to EN ISO 5172
The label of the nozzles indicates the cutting range, the fuel gas, the mixer type
and the required operating pressure of oxygen.
Injector type:
•
Cutting range:
•
Operating pressure for oxygen:
•
Oxygen:
•
Acetylene:
•
Propane:
•
Methane (natural gas):
•
1.2
Components
The torch consists of the handle (1) and the cutting attachment (2). There are
also cutting nozzles (3) and heating nozzles (4) available. Compatible cutting noz-
zles are listed on page 25 and the following page.
The torch has got the following hose connections according to DIN EN 560:
Oxygen:
•
Fuel gas:
•
G1/4 RH (G3/8 RH for Brenner 90 Special)
G3/8 LH
16
e.g. 300 – 500 mm
e.g. 10 bar
O
A
P
M