Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Lincoln Electric INVERTEC 135S Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für INVERTEC 135S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
electromagnetic disturbances. Consider the following.
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

Input Voltage
230V ± 15%
Single Phase
Duty Cycle
(Based on a 10 min. period)
100%
135S
25%
100%
150S
30%
100%
170S
35%
Welding Current Range
135S
150S
170S
Fuse (delayed) or
Circuit Breaker ("D" characteristic) Size
135S
16A
150S
16A
170S
16A
Height
135S
224mm
150S
244mm
170S
244mm
Operating Temperature
-10°C to +40°C
English
Input Power at Rated Output
2.0kW @ 100% Duty Cycle
135S
3.5kW @ 25% Duty Cycle
2.5kW @ 100% Duty Cycle
150S
4.2kW @ 30% Duty Cycle
2.9kW @ 100% Duty Cycle
170S
5.1kW @ 35% Duty Cycle
RATED OUTPUT AT 40°C
Output Current
OUTPUT RANGE
10 – 120A
10 – 140A
10 – 160A
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Power Cable
3 x 1.5mm
3 x 2.5mm
3 x 2.5mm
PHYSICAL DIMENSIONS
Width
148mm
148mm
148mm
INPUT
70A
120A
90A
140A
100A
160A
Maximum Open Circuit Voltage
45Vdc (CE model)
32Vdc (AUSTRALIA model)
2
2
2
Length
315mm
365mm
365mm
Storage Temperature
5
Frequency
50/60Hz
Output Voltage
22.8Vdc
24.8Vdc
23.6Vdc
25.6Vdc
24.0Vdc
26.4Vdc
Type of Plug
(Included with Machine)
SCHUKO 16A / 250V or
AUSTRALIAN 15A / 250V
Weight
4.6kg
6.7kg
7.0kg
-25°C to +55°C
English

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Invertec 150sInvertec 170sInvertec 135s

Inhaltsverzeichnis