Dometic DC-Kit2 Montage- Und Bedienungsanleitung Seite 17

Dc-erweiterungskit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
DC-Kit2
7.4
Connecting the B2200/B1600 Plus Dometic roof air
conditioner
I
NOTE
Connect roof air conditioners with a serial number lower than
802200001 in the way described in chapter "Connecting the B1600
Dometic roof air conditioner" on page 19.
➤ Remove the outlet panel of the roof air conditioner, if necessary also remove the
upper cover ( B2200/B1600 Plus) (fig. 4, page 4).
➤ Join on/off cable for B2200/B1600 Plus to the plug connector on the circuit
board (fig. 5, page 4).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Join the universal connection cable to the on/off cable of the B2200/B1600
Plus.
➤ Connect the universal connection cable with connections I2 and I5 of the
charging current distributor ( ECL-102) (fig. 3 1 and 3, page 4).
➤ Attach the outlet panel of the roof air conditioner ( B2200/B1600 Plus)
(fig. 4, page 4).
➤ Run the connection cable of remote control RC1 to the inverter and connect
( PP2002).
7.5
Connecting the FJ1100, FJ1700, FJ2200, Dometic roof
air conditioner
➤ Remove the outlet panel of the roof air conditioner, if necessary also remove the
upper cover (FJ1100, FJ1700, FJ2200) (fig. 6, page 5).
➤ Join on/off cable for FJ1100, FJ1700, FJ2200 to the plug connector on the circuit
board (fig. 7, page 5).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Join the universal connection cable to the on/off cable of the FJ1100, FJ1700,
FJ2200.