4 - INSTALLATION
4.1) DIMENSIONS
G
B
120
4.2) INSTALLATION GUIDELINES
Installation of device: indipendent - fixed
wall mounting - on the back round box - on rectangular flush
mounting box (3 modules)
install the chronothermostat at a height of 1,5 m from the floor,
far from heat sources, windows and anything that might modify
de standard operational mode.
!
28
4.3) FIXING BASE
Switch off mains power to device
Using screws, fixing the base to the wall at to the back round or
rectangural box using holes provided.
If the chronothermostat base is to be mounted on a metal wall,
apply two special insulating washers to the two screws
A fixing holes
-
B pass wires from back round or rectangular box
-
C
-
27,6
22
OK!
To ensure the chronothermostat is fitted correctly to the wall-
mounted base, care must be taken to ensure that the base is not
h 1,5 m
distorted by screwing the rectangular back box too tightly to the
wall.
A
fixing clips of chronothermostat
C
A
6 7 8 9
B
C
.
3 2 1
A