Herunterladen Inhalt Inhalt Diese Seite drucken

CTEK MXS 10 Bedienungsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für MXS 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
CHARGING PROGRAM
DESULPHATION
1
1
15.8V
10A until 12.6V
NORMAL
15.8V
10A until 12.6V
AGM
15.8V
10A until 12.6V
RECOND
SUPPLY
Limit:
Max 8h
STEP 1 dESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead
plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a
defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
SOFT START
BULK
ABSORPTION
2
3
Increasing voltage
14.4V @ 25°C
to 14.4V @ 25°C
Declining current
10A
Increasing voltage
14.7V @ 25°C
to 14.7V @ 25°C
Declining current
10A
Increasing voltage
14.4V @ 25°C
to 14.4V @ 25°C
Declining current
10A
Max 8h
Max 20h
ANALYSE
4
5
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Checks if voltage
Max 15.8V
drops to 12V
1.5A
30 min or 4h
Max 10h
3 minutes
depending on
battery voltage
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be replaced.
STEP 6 RECONd
Choose the Recond program to add the Recond step to the charging process. During the Recond step
voltage increases to create controlled gasing in the battery. Gasing mixes the battery acid and gives
back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and gives a
pulse when necessary to keep the battery fully charged.
RECOND
FLOAT
6
7
13.6V
12.7V‒14.4V
10A
10‒2A
13.6V
12.7V‒14.7V
10A
10‒2A
13.6V
12.7V‒14.4V
10A
10‒2A
Max 13.6V
10A
10 days
Charge cycle restarts
Charge cycle restarts
if voltage drops
if voltage drops*
PULSE
8
EN • 5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis