Follow the procedure below:
K
1
Turn the knurled wick adjustment knob 2 clockwise to its stop (Fig. K). If you
apply more pressure you may turn it slightly further; however, it will automati-
cally return to the start position. When you have set the wick to its highest positi-
on, this action will automatically activate the safety device.
When you have ignited the heater and it shuts off again shortly after, the batte-
ries need to be replaced. It is best to use new alkaline batteries (4x D-size).
If the heater has been used only a few times and the wick adjustment knob is not
locked, first turn the wick adjustment knob (Fig. L) completely left, before putting
the wick in the highest position for ignition (Section C).
E
After having ignited the heater, always check whether the combustion
chamber D is level, by sliding it slightly to the left and the right by its handle E
(Fig. E). This should be a smooth movement. If the combustion chamber is not
level, this will cause smoke and soot to develop.
L
D
BURNING OF THE HEATER
After you have ignited the heater, it will take 10 to 15 minutes before you can
check whether the heater is burning well. Too high a flame may cause smoke and
soot, whereas too low a flame causes smells. The page opposite the folding page
shows the minimum and maximum permissible burning heights of the flame (Fig. R).
If the flame remains low after the adjustment, the wick height must be
adjusted (refer to Section F).
Burning that is too low may be caused by:
e
insufficient fuel
e
poor fuel quality
e
insufficient ventilation
e
wastage of the wick
S
When there is insufficient ventilation in the room, an intermittent buzzer will be
heard and the VENT lamp (Yellow) will be lit. When this signal is given, ensure
that the ventilation of the room is improved (e.g. by opening a door or window a
little more) to avoid that the heater shuts off. When the ventilation of the room is
improved, the VENT lamp and buzzer will be deactivated. When there is still insuf-
ficient ventilation, the heater shuts off automatically. After improving the ventila-
tion of the room (e.g. by opening a door or window a little more), the heater can
be ignited again.
This heater is fitted with a safety system that ensures that it switches off if you
lift the exchange tank out of the heater for more than 5 seconds. To switch the
heater on again, put the exchange tank back and follow the steps in section C.
(fill the tank)
(contact your dealer)
(put window or door ajar)
(contact your dealer or replace the wick,
refer to section M)