fuel filter
P
THE HEATER SLOWLY EXTINGUISHES
e
The removable tank is empty.
See Section B.
e
The fuel filter is contaminated by water.
Dry the fuel filter (Section H, Fig. P).
e
The lower reservoir is contaminated by water.
Contact your dealer.
e
The wick has hardened on the upper side.
Burn the heater until all fuel is used (Section H). Use the right fuel.
e
You are using fuel which is past its 'use by' date.
Start every heating season with fresh fuel.
THE HEATER REMAINS BURNING LOW
e
Wick position too low.
Reinstall the wick height lock (Section F).
e
Before you refilled the tank, the heater had burnt up almost all the fuel.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
e
You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section 'What you need to know in advance').
e
The room is insufficiently ventilated.
Leave a window or a door wide open for a while.
THE HEATER IS BURNING TOO HIGH
e
You are using an incorrect, too volatile type of fuel.
Refer to THE RIGHT FUEL (See Section 'What you need to know in advance').
e
Wick position too high.
Reinstall the wick height lock (Section F).
H
MAINTENANCE
Your heater needs hardly any maintenance. It is, however, important that you remove
dust and stains in time with a damp cloth, because otherwise these may cause stains that
are hard to remove. Under normal conditions, only two components are subject to wear:
1. THE BATTERIES
You may replace the batteries yourself. Do not dispose of old batteries along with
the other domestic waste. Follow the locally applicable regulations regarding the
disposal of domestic chemical waste.
2. THE WICK
To extend the glass fibre wick life, you must occasionally let the heater burn until
the tank is completely emptied and the heater extinguishes by itself. Do this when
you notice that the flame is weakening. The burn-out will cause some smells, so it
is recommended that you take the heater outside of the living room.
THE FUEL FILTER
Check the fuel filter regularly as well.
Remove the removable tank I from the heater and take out the fuel filter (Fig.
P). Some drops of fuel may spill from the filter; keep a cloth at hand. Turn the
fuel filter upside down and clean it from all dirt deposits by tapping it on a hard
surface. (never clean it with water!) Reposition the fuel filter in the heater.
Do not remove any heater components yourself. Always contact your dealer for
repairs.
4