TROUBLESHOOTING

Malfunction
No Led on the TX and RX
columns on
Orange "Disq." Led on the
receiver column out continually
BIRIS II 100 & 200 only
Red "Alarm" Led on the receiver
column lit continually
BIRIS II 50 only
Red "Alarm" Led on the receiver
column does not light up when
the beams are interrupted
Probable cause
Improper power supply
Transmitter column without
power
Transmission module and
reception module on
different channels
Poor alignment of cells
Object obstructing the beams
The two cells are not
interrupted simultaneously (in
mode "AND")
- 32 -
BIRIS II 50/100/200
Solution
Check power supply (operating
range between 10V and 14V)
Check transmitter power supply
Put the transmitter and receiver
on the same channel, then
switch columns' power off and
on
Re-perform the alignment
procedure
Disengage the beam axes
Interrupt all beams
simultaneously