There are no European rules regarding the minimum distance to non-flammable walls, Westfire recommend leav-
ing a gap of at least 10 cm behind and to sides of stove.
soapstone base and top Plates for the uniQ 16/20
When installing a UNIQ 16 or 20 with Soapstone top plates remove standard louvre grill top plate from stove.
Place soapstone panels directly on top of stove and fit new rear grill to rear. If top flue exit is not used a cover
plate is supplied on the stove to cover flue area.
uniQ 16 & 20 soapstone plates
Height with 10cm plate
Height with 20cm plate
Height with 30cm plate
Base soapstone
When installing a Uniq 16 or 20 with a base soapstone a 12mm floor plate or construction hearth is still to be
installed in accordance with document J regulations.
uniQ 15,16,& 20
Westfire insulated chambers
The Westfire UNIQ 15, 16, 20 wood burning stove is lined with heat deflection panels and baffles, these panels
are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove.
These baffles should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
connection to chimney
Westfire UNIQ 15, 16, 20 wood stove has both rear and top flue connector that allows connection to either a
masonry chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for
"Connection to chimney" given in the instruction booklet.
commissioning and handover
Ensure loose parts are fitted in accordance with the instructions, page 15 & 16. ' Vermiculite fire brick installation
sequence' before handover. Operation of primary and secondary air controls must be fully explained.
WESTFIRE · WF15 · WF16 · WF20
uniQ 16
1160 mm
1260 mm
1360 mm
60 mm
Top flue exit 150 mm
Distance from rear to centre of flue
UNIQ 15:
UNIQ 16 & 20:
Rear flue exit 150 mm
Height to centre of rear flue
UNIQ 15, 16 & 20:
Closed combustion air intake 100 mm
Height to centre of air intake
UNIQ 15, 16 & 20:
9
uniQ 20
1400 mm
1500 mm
1600 mm
60 mm
155 mm
180 mm
960 mm
110 mm