This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
The pump power can only be controlled by an OASE current management unit.
Height and shape of the fountain depends on the nozzle used. The fountain height can also be regulated by turning the
flow regulator on the unit (8) or on the filter wing adapter (10).
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
Remove the unit from the pond for cleaning. Should the performance decline, clean the filter housing (1), the filter
wings (2) and the screen (9).
Important! Never open the pump yourself! Should the rotor be blocked due to soiling, please contact a quali-
fied electrician!
Replace the sealing ring in the nozzle tube
Undo the black union nut and remove the top tube of the nozzle tube, remove the black union nut, replace the sealing
ring, pull the union nut over the top tube and screw securely to the bottom tube, then align the nozzle tube and retigh-
ten using the blue union nut.
Malfunctions
Trouble shooting
Unit does not run
Fountain height insufficient or
inconsistent
After a short period of operation
the unit switches off
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Wear parts
The impeller unit is a wearing part and does not fall under the warranty.
14394-03-14_GA_Aquarius Fountain9 9
Cause
- no mains voltage
- Rotor blocked
- Main flow regulator closed too far
- Nozzle blocked
- Filter/screen clogged
- Rotor soiled
- Hose blocked or defective
- Hose kinked
- Excessive loss due to friction in the hose
- Rotor worn
- Filter/screen blocked
- Filter clogged
- Water temperature too high
Remedy
- check mains voltage
- Clean pump
- Adjust main flow regulator
- Clean nozzle
- Clean filter/screen
- Clean rotor
- Clean hose or replace
- Check hose and replace if necessary
- Reduce hose length to reduce frictional loss
- Replace rotor
- Clean filter/screen
- Clean
- Note maximum water temperature of +35°C