Select fan
2500 m3
Push to confirm
By pressing the PTK, this fan is set as default. When
rebooting the T-2 Pro, these fan settings will be used.
You enter the next screen:
Set the time between
changing the power
level of the box.
5s
Turn the PTK until the desired interval is reached (up to
250 seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a
somewhat longer interval. If the temperature keeps
fluctuating with the current settings, you can change
the interval. If the temperature often increases too high,
it is recommended to shorten the interval. If the
temperature often falls too low, it is recommended to
increase the interval.
Confirm by pressing the PTK.
You return to the boot menu.
System settings
CO2 setup
Box selection
>> HOME <<
Select >> HOME << and press the PTK to return to the
main screen.
16.3 Automatic or manual operation
You are in the main screen. Select line 4: "BOX" is
alternated with "CO cntr" and "dawn/day time/dusk".
Press the PTK.
TMP = 29.8 °C
RH =
63 %
CO2 =
848 PPM
=> BOX 20% Auto
*
CO2 cntr 00:00:00
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Select "BOX A/M".
=> BOX A/M
Auto
BOX min
10%
BOX max
90%
Select box
In the "Auto" mode the fan will automatically run
faster if a measured value is too high. That is, if:
TMP is higher than TMP setpoint + hysteresis;
•
RH is higher than RH setpoint + hysteresis;
•
the lights are off and CO
•
setpoint + hysteresis.
In such a situation, the fan will slowly accelerate.
Between two accelerations the fan will wait the number
of seconds that you set during startup in the next
screen (box delay):
Set the time between
changing the power
level of the box.
5s
When all measured values return to normal (TMP
below TMP set, RH below RH set, CO
below CO
set (during lights OFF) / CO
2
alarm value, the fan will slowly slow down.
ATTENTION: The Auto control only works for the
CO
set when the lights are off. When the lights are
2
on, the Auto control does not respond to the CO
set.
Only if the CO
alarm value is exceeded, the fan will
2
run faster until "BOX max" is reached: this is done
both with lights on and lights off.
The Auto contol always works for TMP and RH.
To set the minimum capacity of the box/fan, select
"BOX min".
BOX A/M
Auto
=> BOX min
10%
BOX max
90%
Select box
To set the maximum capacity of the box/fan, select
"BOX max".
is higher than CO
2
2
2
lower than CO
2
2
35