Via the rs-232 port
Vorschau ausblenden Andere Handbücher für DB1:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
The following commands control the operation of the DB1:
Command
set<SP>0<SP>0
set<SP>0<SP>1
set<SP>3<SP>k
set<SP>36<SP>v
The following messages are sent automatically by DB1:
Message from DB1
<NUL>
SY<SP>PWRUP<CR><LF>
SY<SP>STBY<CR><LF>
SY<SP>STBY<CR><LF>
SY<SP>OPER<CR><LF>
Description
Go to standby
Go to power on
Select preset k+1
where k = 0..4
(ie k = 2 selects preset 3)
Select volume trim v
where v = -6..6 dB
NB Volume trim is used to fine tune
individual programme items. It is
separate from all gains within the main
setup procedure. The value is volatile
and reset to zero when the DB1 is
switched to standby.
Description
Mains power has been connected.
where <NUL> represents the ASCII
value 0
The DB1 has been set to standby.
The DB1 has been set to power on.