6. SERVICE

6.1. Fault identifi cation and repair
In case of any diffi culties during actuation of the device or during its exploitation, please return to these chapters in this ma-
nual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still experience
diffi culties, the following hints will help you solve the problem.
The device is not working... – Make sure that:
The device is connected to the supply network
Voltage and frequency in the network are compliant with those recommended by the producer 230V/50Hz
The main switch is turned on
Thermostat is switched on (Concerns the Igloo thermostat – If only two dots are displayed on the screen – turn on
the thermostat)
The device is operating, the lighting is switched off... – Make sure that:
The lighting switch is on
Fluorescent lamp or the starter of the device are not burnt
Water leakage from under the device
Verify the correctness of device levelling
The device does not reach the proper temperature, the lighting is on...– Make sure that:
The main switch is on
Temperature setting on the thermostat is properly set
The thermostat is operating properly
Make sure that the condenser is not fi lthy, and clean the condenser when necessary
Ambient temperature does not exceed 25ºC
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
(This concerns the "IGLOO" thermostat) thermostat displays C0 or C1 or C2 instead of displaying tempe-
rature: This situation shall occur, when one of temperature regulation sensors has been destroyed. The
following messages may be displayed in such case:
C0 – temperature sensors inside the chamber are damaged – call authorized service
C1 – failure of evaporator sensor - call authorized service
C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service
(This concerns the "CAREL" thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead
of temperature:
E0 – temperature sensors inside the chamber are damaged – call authorized service
E1 – failure of evaporator sensor - call authorized service
L0 – low temperature alarm (lower than temperature range set within the device – call authorized service
HI – high temperature alarm – call authorized service
EE – internal defect of the regulator – call authorized service
Ed – max. defrosting time exceeded
DF – defrosting in progress (this is not an alarm signal)
www.igloo.pl
Fig.8 Assembly/disassembly of the
glass side
1 – ABS side
2 – Glass side
3 – Glass (glass side) press
1
During maintenance services
it is necessary to pay attention
not to damage the data plate of
the device Fig.9 (p.16), which
contains signifi cant information
for servicing organs and waste
removal companies.
User manual RAFAŁ B