6. Commissioning

6.1

Safety information

DANGER - Indicates an unusually high-level hazardous situation. Non-compliance with this warning may result
in serious irreversible injury or death.
WARNING - Indicates an unusually high-level hazardous situation. Non-compliance with this warning may
result in serious, irreversible or fatal injury.
CAUTION - Indicates a hazardous situation. Non-compliance with this warning may result in minor or moder-
ate injury.
DANGER – Explosive atmosphere!
➢ Do not open the device if a potentially explosive atmosphere may be present!
➢ Wait 10 minutes for the electrical components to discharge after switching off the operating
voltage. The device should only be opened afterwards.
DANGER – Observe special conditions (X): (see
➢ The device must be mounted protected against impact.
A protective basket is not absolutely necessary.
Electrostatic discharge!
➢ The device must only be wet-cleaned.
➢ Avoid unintentional and dry rubbing.
An installation height of > 2.50 m or comparable protective measures is therefore sug-
gested.
Vapor tightness control:
➢ Check the seal of the device for cleanliness and damage prior to assembly. Do not use
devices with damaged seals.
➢ Only use approved cable glands. (see
➢ Never operate the device outside the specified ambient temperatures:
T6: -20°C  Ta  +55°C
➢ Never operate the device outside the specified voltage ranges.
DANGER - Danger to life due to electric shock
Voltage-carrying devices and exposed connection cables may cause electric shocks and serious
accidents.
➢ Only trained and authorized electricians may work on electrical connections.
➢ Disconnect all supply lines from mains before installation and secure them against reconnec-
tion. Always ensure absence of voltage.
➢ The operating voltage must only be applied when the housing is firmly closed.
WARNING - Danger due to unauthorized use of the devices
Improper use may lead to serious accidents.
➢ Ensure that the connection cable is protected against pulling and twisting during installation.
The devices are only intended for fixed installation.
DANGER - Hazard due to damage to the devices
Non-compliance with the information on the type plate can lead to serious accidents.
➢ Always observe the information on the type plate when installing and servicing the devices.
➢ Observe the chemical resistance of the polycarbonate plastic.
CAUTION - Risk of injury due to sharp edges or heated components
➢ Wear gloves during any installation, assembly or service/maintenance work.
➢ Perform wiring tasks at a distance from sharp edges, corners and internal components.
CAUTION
➢ Avoid constant, direct glances into the activated lights to prevent impairment of vision.