Replacement of the Active Carbon Filter
The active carbon filter takes care of quality air inside the wine cooler cabinet. In order to maintain its
proper function the active carbon filter should be replaced ca. every 3 months.
The active carbon filter is placed in the left upper corner of the wine cooler cabinet. It is accessible
from the frontside respective inside of the cooler. Dependent on the model type it can be helpful for
the replacement of the active carbon filter to remove the extendable rack which may be placed in front
of it. In order to replace the active carbon filter it can be pulled out of the backwall by turning it while
pulling.
IV
Before Commissioning
1. Before using your new wine storage cabinet, ensure that the parts in bearings(compressor) and the
water collection tank on the back of the cabinet have not shifted and are in their proper place.
2. Place the wine cooler about 10 cm away from the wall so that the heat can be dissipated well (air
circulation). Proper air circulation along the cooling grid will substantially reduce power consumption.
3. Place the wine cooler on a firm, dry and plain-level surface. The cabinet should not be exposed to
temperatures below freezing point, nor to vibrations, pushes or wet environment.
4. With the front leveling screws the cabinet can be plain-leveled so that it stands completely straight,
even if there is any unevenness in the floor.
5. After definitive placement of the wine cabinet it should not be connected to power for the duration
of at least 24 hours! The compressor may be damaged if this instruction isn't followed.
V
Commissioning
1. Connect the power plug to the socket.
2. Fill the wine bottles in the wine cabinet before turning on the power. In the dual zone cooler the
upper zone should be filled with white wine, while the lower (larger) zone is for the red wine.
3. Turn the device 'on' with the "Power" button on the control panel .
4. For Models with active humidifier:
If the right display shows "H2", please refill distilled water.
In the wine chamber on the top left corner in the front the water container is mounted (black).
To refill water into the container, it can be pulled forward.
Please refill the water container with distilled water until it's almost full. Then slide the water
container in the same way back into its original position.