Error No.
02E
low voltage protection
04E
Motor block protection
05E
Drive upper bridge failure
06E
Drive down bridge failure
07E
Hall problem for the motor
08E
high temperature of the motor
09E
Throttle problem
10E
Brake problem
11E
communication failure between instrument and
electronic controller
12E
lnstrument received data timeout failure
13E
The controller cannot read the battery data
15E
Short circuit of motor phase line

7. Error reporting function

Wichtige Hinweise
Error Name
3 9
3 9
Reasons
Batterie voltage lower than 33 V
Motor blocked or short circuit or drive failure
Drive upper bridge MOS tube damaged or
breakdown
Drive down bridge MOS tube damaged or breakdown
Hall line sequence is wrong or poorly connected
Motor temoerature higher than normal working temperature
Hall problem for the throttle or poorly connected
Brake problem or Poorly connected
Instrument sensor problem or poorly connector for the comunica-
tion signal wire
Instrument problem or poorly connector for the comunication
wire
Battery communication connector problem or battery problem
Short circuit of motor phase line when unlocking