Operation
The different operation modes and parameters are set
by a 4-position slide-switch
and a JOG-switch with push-button functionality.
inscription function
+
increment
JOG-switch
push-button
(confirmation of selection)
-
decrement
- light-on/dark-on select;
slide-switch
OUT
- pulse stretching
OPT
- operation modes
TEA
- teach-modes
- signal strength display;
RUN
- selected parameters:
( + = tHi , - = tLo )
- external TEACH
V10 menu navigation
slide-switch
JOG-Switch
selection of
selection with +/-
main menu
confirm with
level 0
level 1
Dark-On/
OUT
Light-On
Output-
Mode
Off Delay
On Delay
Parameter
OPT
lock
Option
Turn dis-
play
Default
Hysteresis
TEA
fully automatic teach
Teach
1-point teach
2-point teach
Fine
tuning
Signal
RUN
0....999
strength
Operati-
+ RemoteTeach
The actual setting is permanently lit up.
Flashing display means: indicated value can be selected. Confirm by pushing JOG-switch.
Technical data
Max. frequency response 10kHz
Functional principle
unpulsed
Power supply indicator
LED green (PWR)
Function indicator
LED yellow (OUT)
Alarm indicator
LED green (PWR)
blinking
Alarm output
200mA, 50ms pulse
length
Operating voltage
10 ... 30VDC (max.)
Output current
200mA
Current consumption
50mA / 50mA
(Ø / peak)
Weight
Casing material
ABS
Operating temperature
-10°C bis +55°C
Protection class
IP54
Caution!
Sensor and amplifier are only intended for object detection. Do not use amplifier and
sensor for personnel safety applications!
JOG-switch
slide-switch
If the green LED is blinking (alarm indicator)
when the amplifier is in operation (RUN), it
indicates an unstable signal. In this case, check
whether the sensor is dirty or out of alignment.
JOG-Switch
JOG-Switch
selection with +/-
selection with +/-
confirm with
confirm with
level 2
level 3
dark-on
light-on
ms
0...250
ms
0...250
n o
Y E S
n o
factory setting
Y E S
Hysteresis in %
3; 6; 9; 12
4 values (default 12)
(see teach-menu)
All automatic teach procedures:
min. value of calculated threshold = 100
max. value of calculated threshold = 850
8...999
Potentiometer
0...999
Threshold low
0...999
Threshold high
Alarm level
0...999
Back to level 1
+
Actual threshold high
0...999
-
Actual threshold low
0...999
Connection
Sensor
M8 connector, 3pole
1 + emitter
4 GND/shielding
3 + receiver
In- /Output
2m PVC-cable 5x0,14
brown
white
blue
black
pink
M12 connector, 5pole
1 (brown)
2 (white)
3 (blue)
4 (black)
output
65g
M8 connector, 4pole
1 (brown)
2 (white)
3 (blue)
4 (black)
SA3: M8 connector, 4pole
1 (brown)
2 (white)
3 (blue)
4 (black)
Mount
Put device onto DIN rail clip as shown.
Then, connect sensor cable.
teach menu and teach instruction
Manipulation
Pushing the JOG-switch activates the teach procedure. Display rdy confirms successful exe-
cution of the teach procedure.
- Repeat teach procedure after every change in hysteresis setting.
- Hysteresis recommendation: For distances > 50% of nominal => use values 9 or 12.
Push JOG-switch to start teach
procedure. Switching threshold
is adjusted by repeated inserting
and removing of the object in the
sensing beam.
Pushing of the JOG-switch
terminates the procedure.
The object is placed statically in
the sensing beam.
Single push on the JOG-switch
executes the teach procedure.
Positioning of object 1 (resp.
distance 1) in the sensing beam
=> Push JOG-switch;
Positioning of object 2 (resp.
distance 2) in the sensing beam
=> Push JOG-switch
Manual fine tuning of all relevant
parameters:
- for optimisation after automatic
teach or
- as fully manual adjustment
without automatic teach.
(Only recommended for pro-
cesses which cannot be adjusted
by one of the automatic pro-
cedures or for correction of an
automatic teach )
Remote teach procedure
The switching threshold of the amplifier can be
adjusted remotely through the PLC via the
teach-input (pink/grey).
(N.B.: only in RUN mode!).
The remote teach procedure is
actuated by two pulses from the
PLC to the amplifier. The duration
of the first pulse selects the teach
mode (automatic or 2-point).
The duration of the second pulse
defines the storage of the deter-
mined threshold value.
1.) X = 2,0 - 4,5s:
2.) X = 0,1 - 1,5s:
Wiring
4
3
1
+ VDC
alarm output
- GND
signal output
PNP
remote teach
4
3
+ VDC
alarm output
- GND
5
signal
1
2
+ VDC
alarm output
- GND
4
2
signal output
3
1
+ VDC
remote teach
- GND
signal output
NPN
Dismount
First unplug sensor cable connector.
Then take amplifier off the DIN rail clip as shown.
Action
The nominal switching
threshold is calculated as
mean value of the detected
high und low signal level.
ALH, tHi und tLo are deter-
mined referring to it depen-
dent on selected hysteresis.
Nominal switching threshold,
ALH, tHi, and tLo are adjusted
automatically refer-ring to the
signal level in a (fixed) relation
to each other.
The nominal switching
threshold is calculated as
mean value between Pt1 and
Pt2.
ALH, tHi und tLo are deter-
mined referring to it depen-
dent on hysteresis.
POt: Adjustment of signal
amplification in 127
potentiometer steps.
tLo: threshold low
tHi: threshold high
ALH: alarm level
rEt: return to level 1
Required voltages
Input voltage
Input voltage
Input current:
a) Fully automatic remote teach:
(running process; preferably
1
several switching cycles)
0,1 - 30 s
2,0 - 4,5 s
0
( teach duration)
b) Remote 2-point teach:
1
0,1 - 1,5 s
0,1 - 30 s
0
teach point (condition1)
Permanent storage (100.000 times max.); The successfull teach procedure is confir-
med by a signal of 100ms duration on the alarm output.
Non permanent storage (until next power cutoff); The successful teach
procedure is confirmed by a signal of 100ms duration on the alarm output.
VDC
brown
teach-in
pink/grey
alarm
white
output
Z
black
L
Z
L
GND
blue
VDC
brown
Z
L
alarm
Z
white
L
output
black
teach-in
pink/grey
GND
blue
Notice
signal
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Especially recommended for cyclic
processes.
signal
2 x hyst.
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Pt1
ALH
hyst.
tHi
hyst.
nom. threshh.
hyst.
tLo
Pt2
Higher signal level should be teached first.
ALH
hyst.
tHi
hyst.
AbS
hyst.
tLo
ALH
tHi
tLo
alarm
output
PNP
NPN
Signal „1":
>9V
<3V
Signal „0":
<5V
>6V
<3mA
<3mA
signal from PLC
X
alarm pulse
signal from PLC
X
alarm pulse
0,1 s
teach point (condition2)
loading