Herunterladen Diese Seite drucken

Grohe TECTRON 37 751 Bedienungsanleitung Seite 5

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and
accessories. The use of other parts will result in
voiding of the warranty and the CE identification,
and could lead to injuries.
Technical data
• Voltage supply:
6V lithium battery type CR-P2
• Minimum delay time:
(2 - 10 s adjustable)
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape:
• Type of fitting protection:
If static pressures exceed 0.5 MPa, a pressure-
reducing valve must be installed.
Installation, see fold-out page I - II
Flush pipes thoroughly before and
after installation (observe EN 806)!
Open hot and cold water supply and
check that connections are watertight.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without
contact
• Battery discharged
(indicator lamp lights up
continuously)
Undesired flushing
• Detection zone of sensor
system set too high
Water flowing
• Solenoid valve defective
continuously
Operation,
see technical product information
99.0438.xxx.
Maintenance, see fold-out page II.
• Function parts must not be greased!
• Close the isolating valve.
• Inspect and clean all parts, replace if
necessary and lubricate with special
grease.
5 s
45 cm
IP 55
Replacement parts
see fold-out page I (* = special
accessories)
.
Care
For directions on the care of this fitting, please refer
to the accompanying Care Instructions.
Remedy
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Reduce detection zone using remote
control (special accessory, prod. no.:
36 407)
- Replace solenoid valve
2

Werbung

loading