Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Remedy Of Faults - Oase LUNAQUA 3 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für LUNAQUA 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Installation and connection

Attention! The unit becomes very hot during operation.
Possible consequence: Combustible materials in the surrounding area could catch fire.
Protective measure: Do not operate the unit in the vicinity of combustible materials.
 A
• Install the transformer at least 2 m from the edge of the pond.
• Position the unit in such a way that it does not present a hazard to anyone.
 B
The unit is supplied fully assembled as a complete set containing one, two or three spotlights, including light bulbs.
When set up above the water level, maintain a safety distance of at least 50 cm from combustible material. Ensure a
safe seating. Covers of the unit are not permissible. Danger of fire! A nozzle holder can be fitted to the spotlight using a
screw connection and clamped to the nozzle tube of an OASE fountain pump (e.g. Aquarius Fountain Set). As an op-
tion, you can bolt on a mounting plate to be pushed on the ground stake, on the foot (for mounting on a firm ground or
a load bearing wall) or on the spotlight holder of an OASE fountain pump. When using a screw connection, ensure that
the nut is placed in the small mounting hole and the screw in the large mounting hole. Position the unit such that it
does not present a hazard for anybody. Connect the power plug of the spotlight to the socket of the transformer / trans-
former supply cable. Plug the transformer plug into the power outlet. Check the spotlight/s function.
Commissioning/start-up
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
• Do not connect the unit to a dimmable power supply.
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Switching on: Insert the power plug of the transformer into the socket.
• Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.
Adjusting the light cone
 B
Attention! Never loosen the union nut! Water might enter the spotlight.
The light angle can be infinitely adjusted from 10° to 40° by turning the focussing ring (6).

Remedy of faults

S
Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S
Cause
Power supply interrupted
Bulb defective
Transformer defective
Lamp glass soiled
The brightness of the bulb reduces as the oper-
ating time increases
Seal defective
Remedy
Check power supply
Replace bulb
Replace transformer
Clean
Replace bulb
Check sealing rings and replace, if necessary
- EN -